Emergency
Disconnect: Easy emergency manual operation using an electrically
interlocked floor level disconnect and hoist mechanism.
Wiring
Type: B2, C2, D1 and E2 wiring types are standard and easily set using
a selector dial on the Logic 3.0 Control Board (L3). T and TS wiring
can be activated with use of a CPS-L or CPS-LN4. Reversing Contactor
Units (M) have C2 wiring standard and B2 available by simply moving
a jumper wire. Operators are pre-wired to accept a sensing edge, photoelectric
sensors, radio controls and most types of access control equipment.
Failsafe wiring can be selected with use of a CPS-L, CPS-LN4 or failsafe
edge and CPS3 card.
External
Radio Control Terminal: Quick, convenient connections for retrofitting
or adding radio controls on logic or mechanical operators.
Bearings:
Industrial ball bearings on a 1" output shaft; heavy-duty oil-filled
iron bearings on reduction shafts.
Friction
Clutch: Adjustable, helps protect against major damage to door and operator
should the door meet an obstruction.
Construction:
NEMA 1 type electrical box, heavy-duty 11-gauge steel frame with durable
powdercoat finish, all reduction sprockets drilled and pinned to shafts.
Push
Button Station: 2-button station for open/close functions is standard
with D or D1 wiring. 3-button station is standard with B2 or C2 wiring.
Positive
Locking Mechanical Brake System: Self-locking mechanical reduction
system that functions as a holding brake.
Control
Accessories
CPS® Commercial Protector System®: (recommended) A “non-contact” photo
safety sensor designed to sense an obstruction and signal the door operator
to reverse to open.
Sensing
Edge: (recommended) Designed to sense an obstruction and signal door
operator to stop or reverse as desired. An electric or pneumatic sensing
device can be added to bottom edge of door.
Available
Plug-in Options for Logic 3.0 (L3)
Auxiliary
Contact: Used to operate security, warning, heating or other 5V to
240V devices. Features both normally open and closed contacts that
actuate in conjunction with limit switches.
Warning
Signal: Red/green light module provides safety warning prior to close
(when using timer-to-close feature). Also supports audio warning devices
and includes down mid-stop feature.
CPS3
Option: Enables the addition of a second set of photo-eyes or 2- or
4-wire, self-monitoring edge.